Colocation Facility Specifications

Ace Data Centers provides an extremely efficient, cost-effective solution for colocation customers. Our facility offers a reliable, secure, and controlled environment for your servers and equipment with a 100% network uptime guarantee.

Building and maintaining your own facility and support staff is a major investment. Fortunately, you can acquire a world class Data Center facility, network, and support services at a fraction of the cost. Let Ace Data Centers, manage your data center infrastructure so you can focus on what you do best -- your business.

We support basic server colocation through a fully managed solution (coming soon!). Our solution is custom designed for each customer, no two solutions are exactly alike. Call us today for a quote.

Physical

  • - 8,500 Raised floor space
  • - 52u high-density cabinets, 394 total

Cabinets

  • - Choice of ¼ Rack, ½ Rack, or Full Cabinets
  • - Turnkey 52u 19" high-density cabinets installed and ready (manufactured by Rittal)
  • - Front & back lockable doors available for additional security
  • - Housed in fully to semi-private "pods." (20) cabinets per pod.
  • - 30A 208V Zero-U PDUs installed to each Cabinet.

Power

  • - Redundant A+B power to each cabinet
  • - 3 sets of Dual segregated transformers
  • - Redundant critical power paths and full bypass capability
  • - (6) 750KW UPS' w/ additional UPS added if needed
  • - 120 UPS battery time at peak load (minutes)
  • - (3) 2 meg N+1 generators, 3,500 gallon fuel storage each, priority 24/7 refueling contracts. Wired in parallel. Additional generator installation space allocated for install when needed.
  • - Raritan PX-5522/5524 PDU included standard. (Customers may use their own PDU if preferred)
  • - Power delivered at 208v. remote monitoring, reboot supported via web portal.
  • - Extremely efficient power efficiency with average yearly PUE under 1.2

Cooling

  • - Fully segregated hot AND cold aisles
  • - N+1 Redundant Chillers
  • - N+2+ redundancy cooling providing 750 tons of total cooling capacity.
  • - Colocation floor cooled by (12) 60-ton and (1) 30 Liebert CRAC units.
    - 36" raised floor throughout
  • - Data Center uses 100% outside air the majority of the year
  • - Fully automated control system, includes alerting and fault detection with automatic backup units
  • - 66 ±4 Air temperature (°F) in cold aisle

Fire Suppression

  • - Laser scanner smoke and heat detection system for early detection
  • - State of the art misting fire suppression system
  • - Nitrogen based fire suppression system, uses just 4% water of standard sprinklers
  • - Nearly zero wetting of protected areas; no need for costly clean up or equipment replacement
  • - Dry pipe sprinkler & Pre-action sprinkler
  • - Green design that is 100% safe for the environment and personnel
  • - Quick system recharge; minimal facility downtime
  • - No need for assurance of tight room integrity
  • - Vicaulic Vortex full brochure (5.64 MB PDF)

Connectivity

  • - Over 120G capacity (expandable to over 1TB) fiber transport connectivity to the internet backbone
  • - 10Gigabit Ethernet network backbone
  • - Redundant fiber connections on diverse physical paths
  • - Redundant telecom and fiber providers
  • - Unrestricted dedicated 100/1000 Mbs or 10 Gig ports on our switch

Security

  • - Secure facility with strict surveillance of visitors and limited access to data center
  • - Over 100 full motion video camera providing 24x7 CCTV video surveillance of exterior perimeter and interior areas
  • - Perimeter and interior card key access control system with 24/7 security monitoring on logging
  • - Mantraps and biometric hand scanners at all Data Center entry points and key internal check points
  • - Access controlled photo badge required to pass though over 90% of all internal building doors
  • - Semi-private cabinet suites provide an additional layer of key card authentication and include 24/7 video surveillance
  • - 24/7 manned security on-site

Environmental Systems

  • - Redundant computer grade Liebert HVAC environmental cooling systems
  • - Redundant UPS power systems (optional A + B power feeds)
  • - Diesel generator back-up system can run at full capacity for weeks with emergency refueling as needed
  • - Pre-Action Dry Pipe fire suppression system with computer controlled early smoke detection monitoring
  • - 36" Raised access floor system

No-Charge Extras

  • - Visual checks with phone support
  • - Use of server lift equipment
  • - Reset cables
  • - Power cycles
  • - Portable monitors and keyboards
  • - Use of tech benches and tools
  • - Competent, friendly, expert service and staff

Managed Services

  • - Equipment installation
  • - Cabling, wiring, and cross-connects
  • - Equipment monitoring
  • - First line equipment and network maintenance
  • - Equipment diagnostic and repair
  • - Monitoring
  • - IP bandwidth
  • - Data backup
  • - Other data management services